Preparing for the Dell SONiC Deploy Exam (D-SNC-DY-00) certification exam can be time-consuming and expensive. That's why we guarantee that our customers will pass the prepare for your Dell SONiC Deploy Exam (D-SNC-DY-00) exam on the first attempt by using our product. By providing this guarantee, we save our customers both time and money, making our D-SNC-DY-00 Practice material a wise investment in their career development.
Are you organized for this? Do you want to end up a EMC certified? In case your answer is high great then we guarantee you that you are on the right region. Check in yourself for Dell SONiC Deploy Exam (D-SNC-DY-00) certification examination and download the D-SNC-DY-00 exam questions and begin preparation right now.
>> D-SNC-DY-00 Valid Braindumps Sheet <<
The most notable feature of the D-SNC-DY-00 learning quiz is that they provide you with the most practical solutions to help you learn the exam points of effortlessly and easily, then mastering the core information of the certification course outline. Their quality is much higher than the quality of any other materials, and questions and answers of D-SNC-DY-00 Training Materials contain information from the best available sources. Whether you are newbie or experienced exam candidates, our D-SNC-DY-00 study guide will relieve you of tremendous pressure and help you conquer the difficulties with efficiency.
NEW QUESTION # 27
Enterprise SONiC Switch 1 and Switch 2 are part of a symmetric VXLAN fabric in a data center environment.
Switch 1 has learned MAC addresses from its local VLANs.
What role does BGP EVPN play in this scenario?
Answer: A
Explanation:
BGP EVPN (Border Gateway Protocol Ethernet VPN) is used in a VXLAN fabric to distribute MAC address reachability information between switches. In this scenario, Switch 1 uses BGP EVPN to advertise the locally learned MAC addresses to Switch 2. This distribution of MAC addresses enables the switches to build and maintain an efficient forwarding table, facilitating communication across the VXLAN fabric.
References:
* Dell Technologies SONiC documentation
* BGP EVPN Configuration Guide
NEW QUESTION # 28
Refer to the exhibits.
PC1 has a valid address on the 192.168.10.0 network, and PC2 has a valid address on the 192.168.20.0 network.
What happens when a ping command is issued between PC1 and PC2?
Answer: D
Explanation:
* Network Topology Analysis:
* PC1 is on VLAN 10 with an IP address in the 192.168.10.0/24 subnet.
* PC2 is on VLAN 20 with an IP address in the 192.168.20.0/24 subnet.
* The network uses OSPF for routing between the switches.
* The OSPF area is 0, and all switches have loopback interfaces for OSPF.
* Routing Table Examination (from switch1):
* The show ip route command output from switch1 provides a detailed look at the routing table.
* Routes to the 192.168.10.0/24 network (directly connected via Vlan10) are present.
* No routes to the 192.168.20.0/24 network are listed in switch1's routing table.
* Explanation:
* For PC1 to communicate with PC2, switch1 must have a route to the 192.168.20.0/24 network.
* The absence of a route to the 192.168.20.0/24 network in switch1's routing table means that switch1 cannot forward packets destined for 192.168.20.0/24.
* Therefore, any ping from PC1 to PC2 will be unsuccessful as switch1 does not know how to route packets to PC2's network.
* Verification with Dell SONiC:
* In Dell SONiC environments, OSPF is configured to ensure dynamic routing.
* The configuration must include all necessary networks for inter-switch routing.
* If a network (like 192.168.20.0/24) is not included in OSPF configurations on switch1, routes to that network will not be advertised or learned, leading to failed connectivity tests like the ping from PC1 to PC2.
References:
* Dell Enterprise SONiC Deployment Guide
* Dell Technologies Networking - SONiC
NEW QUESTION # 29
An administrator for a service provider uses this command on a switch:
What is the result of running the command?
Answer: B
Explanation:
The command interface vxlan vtep-stacking followed by map vni 10010 vlan 100 maps the VLAN traffic that an SVLAN identifies to a VNI on a VTEP. In this context, SVLAN (Service VLAN) is being mapped to a VXLAN Network Identifier (VNI) for encapsulation and transport across the VXLAN tunnel.
References:
* Dell Technologies SONiC documentation
* VXLAN Configuration Guide
NEW QUESTION # 30
An administrator obtains the following CLI output:
How much time does the local system take to detect remote failures without receiving packets?
Answer: C
Explanation:
The local timers in the BFD (Bidirectional Forwarding Detection) configuration show a detect multiplier of 4 and a receive interval of 300ms. The time taken to detect remote failures is calculated as detect multiplier × receive interval = 4 × 300ms = 1200ms.
References:
* Dell Technologies SONiC documentation
* BFD Configuration Guide
NEW QUESTION # 31
Use the simulator to perform the following configuration task.
1. Map a single-tagged CVLAN 100 to SVLAN 200 translation on PE
switch interface Eth1/1.
2. Map a double-tagged VLAN packet with an outer CVLAN 100 and an
inner dot1q 200 to SVLAN 300 translation on PE switch interface
Eth1/2.
The necessary VLANs and VLAN stacking have already been configured.
Answer:
Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required VLAN translations on a Dell SONiC switch:
* Map a Single-Tagged CVLAN 100 to SVLAN 200 on Interface Eth1/1:
sonic# configure terminal
sonic(config)# interface Ethernet1/1
sonic(config-if-Ethernet1/1)# switchport mode trunk
sonic(config-if-Ethernet1/1)# switchport vlan mapping 100 200
sonic(config-if-Ethernet1/1)# end
sonic# write memory
* Map a Double-Tagged VLAN Packet with Outer CVLAN 100 and Inner dot1q 200 to SVLAN 300 on Interface Eth1/2:
sonic# configure terminal
sonic(config)# interface Ethernet1/2
sonic(config-if-Ethernet1/2)# switchport mode trunk
sonic(config-if-Ethernet1/2)# switchport vlan mapping 100 200 300
sonic(config-if-Ethernet1/2)# end
sonic# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Access the global configuration mode using the configure terminal command.
* Configure Interface Eth1/1:
* Enter interface configuration mode for Ethernet1/1 using the command interface Ethernet1/1.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the VLAN translation using the switchport vlan mapping 100 200 command, which maps CVLAN 100 to SVLAN 200.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
* Configure Interface Eth1/2:
* Enter interface configuration mode for Ethernet1/2 using the command interface Ethernet1/2.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the double-tagged VLAN translation using the switchport vlan mapping 100 200 300 command, which maps packets with outer CVLAN 100 and inner dot1q 200 to SVLAN 300.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure VLAN translations on a Dell SONiC switch, ensuring that the specific requirements for single-tagged and double-tagged VLAN mappings are met.
NEW QUESTION # 32
......
For candidates who are going to choose the D-SNC-DY-00 training materials online, the quality must be one of the most important standards. With skilled experts to compile and verify, D-SNC-DY-00 exam braindumps are high quality and accuracy, and you can use them at ease. In addition, D-SNC-DY-00 exam materials are pass guarantee and money back guarantee. You can try free demo for D-SNC-DY-00 Exam Materials, so that you can have a deeper understanding of what you are going to buy. We have online and offline chat service stuff, and if you have any questions for D-SNC-DY-00 exam materials, you can consult us.
D-SNC-DY-00 Reliable Test Voucher: https://www.test4sure.com/D-SNC-DY-00-pass4sure-vce.html
EMC D-SNC-DY-00 Valid Braindumps Sheet Why should people choose our, Our D-SNC-DY-00 test preparation materials are not just your regular PDF with questions with boring reading routines, This greatly improves the students' availability of fragmented time to study our D-SNC-DY-00 learning guide, To obtain the EMC D-SNC-DY-00 Reliable Test Voucher certificate is a wonderful and rapid way to advance your position in your career, You have no need to spend extra money updating your D-SNC-DY-00 Reliable Test Voucher - Dell SONiC Deploy Exam exam study materials; we will ensure your one-year free update.
This was the largest increase ever in business applications Exam D-SNC-DY-00 Overview and there s nothing even close, They are exactly what I have been waiting for: i.e, Why should people choose our?
Our D-SNC-DY-00 Test Preparation materials are not just your regular PDF with questions with boring reading routines, This greatly improves the students' availability of fragmented time to study our D-SNC-DY-00 learning guide.
To obtain the EMC certificate is a wonderful and rapid way to advance your D-SNC-DY-00 position in your career, You have no need to spend extra money updating your Dell SONiC Deploy Exam exam study materials; we will ensure your one-year free update.